Potterton Paramount three 30 Installation Manual page 66

Hide thumbs Also See for Paramount three 30:
Table of Contents

Advertisement

Programming
Function
Function input H1
None | Optg mode change HCs+DHW | Optg mode change DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK2 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention | Con-
sumer request VK1 10V | Consumer request VK2 10V | Preselected
output 10V
Contact type H1
NC | NO
Voltage value 1 H1
Function value 1 H1
Voltage value 2 H1
Function value 2 H1
Function input H4
None | Optg mode change HCs+DHW | Optg mode changeover DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK21 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention | Flow
measurement Hz
Contact type H4
NC | NO
Frequency value 1 H4
Function value 1 H4
Frequency value 2 H4
Function value 2 H4
Function input H5
None | Optg mode change HCs+DHW | Optg mode changeover DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK21 | Release swi pool source | Excess heat discharge | Re-
lease swi pool solar | Operating level DHW | Operating level HC1 | Op-
erating level HC2 | Operating level HC3 | Room thermostat HC1 |
Room thermostat HC2 | Room thermostat HC3 | DHW thermostat |
Pulse count | Checkb sign flue gas damper | Start prevention
Contact type H5
NC | NO
Function extension module 1
None | Multifunctional | Heating circuit 1 | Heating circuit 2 | Heating
circuit 3 | Solar DHW | Primary contr/system pump
66
Prog.
5950
5951
5953
5954
5955
5956
5970
5971
5973
5974
5975
5976
5977
5978
6020
Paramount three 30-115 kW
Standard value
1)
Level
no.
C
None
C
NO
E
0,5
E
0
E
10
E
1000
C
None
C
NO
E
0
E
0
E
0
E
0
C
None
C
NO
C
Heating circuit 2
7308272-03 03.14