Programming
Function
Optg mode changeover
None | Protection | Reduced | Comfort | Automatic
DHW
Nominal setpoint
Reduced setpoint
Release
24h/day | Time programs HCs | Time program 4/DHW
Charging priority
Absolute | Shifting | None | MC shifting, PC absolute
Legionella function
Off | Periodically | Fixed weekday
Legionella funct periodically
Legionella funct weekday
Monday | Tuesday | Wednesday | Thursday | Friday | Saturday | Sun-
day
Legionella funct time
Legionella funct setpoint
Legionella funct duration
Legionella function circ pump
Off | On
Circulating pump release
Time programme 3 / HCP | DHW release | Time programme 4/DHW |
Time program 5
Circulating pump cycling
Off | On
Circulation setpoint
Optg mode changeover
None | Off | On
Consumer circuit 1
Flow temp setp cons request
DHW charging priority
- No | Yes
Excess heat draw
- Off | On
With buffer storage tank
- No | Yes
With prim contr/system pump
- No | Yes
Consumer circuit 2
Flow temp setp cons request
DHW charging priority
No | Yes
Excess heat draw
Off | On
With buffer storage tank
No | Yes
58
Prog.
1500
1610
1612
1620
1630
1640
1641
1642
1644
1645
1646
1647
1660
1661
1663
1680
1859
1874
1875
1878
1880
1909
1924
1925
1928
Paramount three 30-115 kW
Standard value
1)
Level
no.
E
Protection
Eu
55°C
E
45°C
Eu
Time program 4/DHW
E
MC shifting, PC absolute
E
Fixed weekday
E
7
E
Sunday
E
- - -
E
65°C
E
- - - min
E
On
C
DHW release
C
On
E
55°C
E
Off
C
70°C
E
Yes
E
ON
E
Yes
E
Yes
C
70°C
E
Yes
E
ON
E
Yes
7308272-03 03.14