Oki Data CONFIDENTIAL
(4) Release the cover AssyMPT ① at the left side first and then the right side. (Be
careful not to deform the spring on the right-lower end side.)
(5) Detach the front cover Assy. (Refer to section 4.2.17)
(6) Remove the seven screws ② , disconnect the ground cable ③ , and detach the
frame Assy. front ④ . (Two stays come off at the same time, too)
①
45850101TH Rev.1
④
②
②
Stay
②
②
②
(7) Remove the seven screws ⑤ and detach the plate-front-FG ⑥ .
(8) Remove the five screws ⑦ and detach the guide Assy ⑧ .
(9) Remove a E-ring ⑨ and detach the clutch ⑩ .
(10) Remove the paper-end-switch ⑪ and detach the cable ⑫ .
(11) Remove the slider-switch ⑬ and detach the spring ⑭ .
(12) Remove the FFC-cable ⑮ .
(13) Disconnect the FFC-cable from the environment sensor ⑯ and detach the
environment sensor ⑯ .
⑯
②
Stay
⑬
⑭
③
4. REPLACEMENT OF PARTS
⑥
⑤
⑦
⑫
⑦
⑪
⑦
⑧
⑦
⑩
⑨
⑮
⑤
⑤
4-44