No. Category PJL Status
Panel messages
Code
47 Error
40967
48 Error
40967
49 Error
40967
50 Error
40967
Please check data.
Program Data
Write Error
<%DLCODE%>
51 Error
-
Shutdown in
progress.
52 Error
-
53 Error
-
54 Fatal
40057
Power Off and Wait
126
for a while
126:Condensing
-
Error
55 Fatal
40057
Power OFF/ON
<nnn>
%ERRCODE%:Error
-
56 Fatal
40057
Inspection is required.
<nnn>
%ERRCODE%:Error
-
45850101TH Rev.1
Description
An error has happened while the printer is
receive-processing the NIC download data.
%DLCODE%
1: File size error
2: Check-sum error
3: Invalid printer model number
4: Invalid module I/F version
5: Invalid FAT version
The printer is writing the NIC download data.
The printer finished writing the NIC download
data.
An error has happened while the printer is writing
the NIC download data.
%DLCODE%
1: Memory allocation error
2: Download file error
3: Device allocation error
4: No device space
5: File writing failure
6: CU-F/W mismatch
It is shown that a unit is shutting down.
Indicates that the printer has completed shutting
down.
It is shown that the printer completed shutdown
processing.
A dew is formed.
The message of fatal error is specified by English
only.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
The message of fatal error is specified by English
only.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
The message of fatal error is specified by English
only.
No. Category PJL Status
Panel messages
Code
57 Fatal
40057
Inspection is required.
096
%ERRCODE%:Error
231
%CODE%
128
-
168
169
58 Fatal
40057
Power OFF/ON
002~011
%ERRCODE%:Error
F0C
F0D
-
FFE
FFF
59 Fatal
40057
Power OFF/ON
9xx
%ERRCODE%:Error
-
60 Error
40735
Insufficient
memory.
40759
40748
Please see Help for
40591
details.
40710
61 Error
40788
Automatic
document feeder
(ADF) cover is
open.
Press the [Details]
button for help.
2. TROUBLESHOOTING PROCEDURES
Description
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%CODE%' specifies error code that is the
detailed error cause. (2 digits, hexadecimal)
The message of fatal error is specified by English
only.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code. F0C, F0D, FFE, and FFF are hexadecimal
code.
The message of fatal error is specified by English
only.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
The message of fatal error is specified by English
only.
Indicates that Memory Overflow is occurred
during the following functions executing.
- Memory Overflow is occurred during the
executing of copy.
- Memory Overflow is occurred during the
executing of Scan To mail.
- Memory Overflow is occurred during the
executing of Scan To Network PC.
- Memory Overflow is occurred during the
executing of Scan To USB memory.
- Memory Overflow is occurred during the
executing of Fax sending.
Indicates that ADF cover of scanner unit is
opened.
Indicates that inter-lock cover of scanner unit is
lifted up.
Notes: If inter-lock cover is lifted up during
scanning from document feeder, system will
display document jam.
2-22