RX-V567/HTR-5063
17. USB
Not for service.
18. IF STATUS (Input function status)
Not for service.
19. BUS CHECK
Communication and bus line connection between
devices on the DIGITAL P.C.B. are checked.
19-1. TI (DSP) BUS check
Communication and bus line connection
between microprocessor (IC20) and TI (DSP,
IC44) are checked.
NoEr:
No error detected.
Boot:
When "Boot" is displayed for a few
seconds or "Boot" and "NoEr" are
displayed alternately, there is a possibility
that an error had occurred.
19-2. BF LOOP check
Not for service.
20. NO MENU
Not for service.
52
1 7 : U S B f i l e 1
D S T : 7 1 0 E 0 F 2 3 9 0
T I B U S : N o E r
B F L O O P :
2 0 . I n v a l i d i t y
17. USB