● Starting Self-Diagnostic Function
While pressing the "TONE CONTROL" and "INFO" keys of
this unit as shown in the figure below, press the " " (Power)
key of this unit to turn on the power.
The self-diagnostic function mode is activated.
While pressing these keys, turn on the power. / これらのキーを押しながら、 電源を入れます。
● Starting Self-Diagnostic Function in
the protection cancel mode
If the protection function works and causes hindrance to
trouble shoot, cancel the protection function as described
below, and it will be possible to enter the self-diagnostic
function mode.
(The protection functions other than the excess current
detect function will be disabled.)
While pressing the "TONE CONTROL" and "INFO" keys
as shown in the figure above, press the " " (Power) key
to turn on the power and keep pressing those 2 keys and
the " " (Power) key for 3 seconds or longer.
The self-diagnostic function mode is activated with the
protection functions disabled.
In this mode, the "SLEEP" segment of the FL display of
this unit flashes to indicate that the mode is self-diagnos-
tic function mode with the protection functions disabled.
CAUTION!
Using this product with the protection function disabled
may cause further damage to this unit. Use special care
for this point when using this mode.
26
● ダイアグの起動
本機の下図に示す TONE CONTROL と INFO キーを押
しながら
ダイアグが起動します。
Keys of this unit /
本機キー
● プロテクション解除モードでの起動
プロテクションが動作することにより、故障箇所の診断
に支障をきたすような場合は、次の方法によりプロテク
ションを解除した状態でダイアグモードに入ることがで
きます。
(過電流検出以外のプロテクション動作を解除する)
上図に示す TONE CONTROL と INFO キーを押しなが
(パワー)キーを押して電源を入れ、 2 つのキーと
(パワー)キーを 3 秒以上押し続けます。
プロテクション解除モードでダイアグが起動します。
このモードでは本機 FL の SLEEP セグメントが点滅し、
プロテクションを解除した状態でのダイアグモードであ
ることを知らせます。
注意!
プロテクションを解除した状態でのダイアグモードは、
危険な状態でもプロテクションが作動しないため、動作
させると、機器を破壊することがあります。このモード
を使用する場合は十分注意してください。
(パワー)キーを押して電源を入れます。