### ibrix_vs -l
### ibrix_vs -l -s
###
Auto registration of chassis and vs completed
5.
Verify that the new vendor storage is now registered with the new storage cluster UUID by
executing the following command:
ibrix_vs -l -s
In the following output example, the vendor storage is now identified by the cluster ID noted
in the command output of step 1.
Command output example:
SERVER_NAME
VENDOR_STORAGE
-----------
---------------------------------------
ib25-12s1
vs_04a1fc68-0000-1000-b021-533457303031
ib25-12s2
vs_04a1fc68-0000-1000-b021-533457303031
6.
Discover LUNs for the new vendor storage by executing the following command:
ibrix_vs -a -n <new cluster ID>
Command output example:
[root@ib25-12s2 ~]# ibrix_vs -a -n vs_04a1fc68-0000-1000-b021-533457303031
Starting discovery of vendor storage LUNs
Starting discovery of vs_04a1fc68-0000-1000-b021-533457303031's LUNs on engine(s)
[ib25-12s1, ib25-12s2]
adding LUN: ID= 6FF4242573000010B0E4533457303244 PV = d19
adding LUN: ID= 6846FF2673000010B0E9533457303244 PV = d24
adding LUN: ID= 66EA6A2373000010B0DE533457303244 PV = d13
adding LUN: ID= 62CEF82573000010B0E6533457303244 PV = d21
adding LUN: ID= 6790BD2273000010B0DC533457303244 PV = d11
adding LUN: ID= 6217792273000010B0DB533457303244 PV = d10
adding LUN: ID= 6A7A8D2473000010B0E2533457303244 PV = d17
adding LUN: ID= 6BD5D82473000010B0E3533457303244 PV = d18
adding LUN: ID= 6731F52373000010B0E0533457303244 PV = d15
adding LUN: ID= 6DBD3C2273000010B0DA533457303244 PV = d9
adding LUN: ID= 6864822073000010B0D4533457303244 PV = d3
adding LUN: ID= 60FCBA2673000010B0E8533457303244 PV = d23
adding LUN: ID= 6486F81F73000010B0D2533457303244 PV = d1
adding LUN: ID= 6277982573000010B0E5533457303244 PV = d20
adding LUN: ID= 6D74F52173000010B0D9533457303244 PV = d8
adding LUN: ID= 694DC62073000010B0D5533457303244 PV = d4
adding LUN: ID= 641F422473000010B0E1533457303244 PV = d16
adding LUN: ID= 686C682673000010B0E7533457303244 PV = d22
adding LUN: ID= 6B93AD2373000010B0DF533457303244 PV = d14
adding LUN: ID= 6BD13D2073000010B0D3533457303244 PV = d2
adding LUN: ID= 61795D2173000010B0D7533457303244 PV = d6
adding LUN: ID= 6599A72173000010B0D8533457303244 PV = d7
adding LUN: ID= 6381172373000010B0DD533457303244 PV = d12
adding LUN: ID= 63B0112173000010B0D6533457303244 PV = d5
Finished discovery of vendor storage LUNs
Command succeeded!
HARDWARE_UNIT_TYPE
------------------
8800
8800
Recovering from a changed storage cluster UUID