Remote Control Thermostat - Travis Industries Spirit DV Owner's Manual

Freestanding direct-vent stove
Table of Contents

Advertisement

O
PTIONAL
P
30
AGE
Remote Thermostat
!
Do not connect 110-120 VAC to the gas control valve or wiring system of this unit.
¥
Follow the instructions included with the remote thermostat for installation.
IMPORTANT OPERATIONAL NOTE FOR REMOTE THERMOSTAT USE:
Included with the remote thermostat is a set of instructions that should be given to the homeowner.
Please be aware that the remote thermostat has a 1 to 2 minute lag time between the time the
thermostat is turned up and the heater turns on.
Propane Conversion Kit
The propane conversion kit should be installed prior to installing the heater (if not, shut off gas
and disconnect the heater from the gas line).
Items Needed For Assembly
¥ 1/4" Nutdriver
¥ Phillips Screwdriver
¥ Thread sealant
Packing List
¥ LP Orifice (#50 - stamped "50")
¥ Two Replacement Screws
Installation Instructions
1 Remove the door and glass to access the firebox (see pages 16 and 15).
2 Reach into the firebox and remove the rear log shelf (see illustration below).
NOTE: When installed, the log
shelf must maintain a parallel
3/8Ó gap to the burner pan.
E
(C
QUIPMENT
(Part # 989000746)
¥ 7/16" and 1/2" Open End Wrench
¥ Micro (1/16") Standard Screwdriver
¥ Leak Testing Equipment
¥ LP Pilot Orifice (.016" dia. - stamped "16LP")
¥ Regulator Gasket
The rear log shelf slides on and off the
burner pan assembly
)
ONTINUED
Make sure the two tabs
slide over the side of the
burner pan on both sides.
¥ Standard Screwdriver
¥ Replacement Regulator
¥ LP Label
Rear
Rear
Log
Log
Shelf
Shelf
Burner Pan
Assembly
Position the
shelf so the
back edges
of the shelf
and burner
pan are flush.