Approved Vent Config's With No Elbows Or Two 45° Offsets (Vertical Term.) - Travis Industries Spirit DV Owner's Manual

Freestanding direct-vent stove
Table of Contents

Advertisement

S
TOVE
P
10
AGE
Approved Venting Configurations for
Vertical Terminations with (or
without)Two 45° Offsets
¥
10' Minimum Height (with or without
offsets)
¥
33' Maximum Height
¥
6' Maximum Offset
¥
Use restrictor position indicated by the area
that your termination falls in
Vertical
Rise
Offset Length
None
1' Section
2' Section
3' Section
4' Section
4' + 1' Section
4' + 2' Section
4' + 3' Section
4' + 4' Section
I
NSTALLATION
Horizontal
Offset
Offset
Length
Hor. Offset
Vert. Rise
5"
1'
1' 7"
1' 9"
2' 4"
2' 5"
3' 2"
3' 8"
3' 9"
4' 4"
4' 6"
5' 2"
5' 9"
6'
6' 9"
(C
.) -
ONT
For qualified installers only!
33' (max)
30 feet
25 feet
20 feet
15 feet
10 feet
(min.)
1'
3'
5 feet
5'
0 feet
Restrictor
Position # 7
28' 6"
NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position
may vary slightly,
especially when the
termination is near
a demarkation line.
Restrictor
Position # 5
The maximum
offset lengths is
two 4' sections.
30 feet
25 feet
20 feet
15 feet
10 feet
(min.)
5 feet
0 feet

Advertisement