Pdas/Mobility Systems Devices; Changing The Scanner's Bluetooth Pin Code; Minimizing Bluetooth/Ism Band Network Activity; Auto Reconnect Mode - Honeywell Xenon 1900 User Manual

Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

PDAs/Mobility Systems Devices

You may also use the scanner with a PDA or a Honeywell Mobility Systems device. Scan the bar code below and follow the
instructions supplied with your Bluetooth device to locate the scanner, and connect with it.

Changing the Scanner's Bluetooth PIN Code

Some devices require a PIN code as part of the Bluetooth security features. Your scanner's default PIN is 1234, which you
may need to enter the first time you connect to your PDA or PC. The PIN code must be between 1 and 16 characters. To
change the PIN, scan the bar code below and then scan the appropriate numeric bar codes from the
inside the back cover of this manual. Scan Save to save your selection.

Minimizing Bluetooth/ISM Band Network Activity

The settings described below can help you customize the relinking behavior of the cordless area-imaging system to obtain the
best compromise between convenience and low interference.
Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth.

Auto Reconnect Mode

Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is
detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without
user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off.
The table below shows the results of the Auto Reconnect On and Off settings:
Event
Scanner out of range
3 - 24
BT Connection - PDA/Mobility Systems Device
Bluetooth PIN
Auto Reconnect On
Relink occurs automatically. If maximum
number of link attempts is unsuccessful,
then the scanner must be relinked by
either pulling the trigger, placing the
scanner in the base, or scanning the
Access Point linking bar code. (See
"Maximum Link Attempts" on page 3-25.)
Programming Chart
Auto Reconnect Off
Auto Reconnect Off
The scanner is relinked by pulling the
trigger, or scanning the Access Point
linking bar code.