RS232 Receiver Time-Out

The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the time-
out. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out. A trans-
action on the CTS line will also wake up the receiver. The receiver takes 300 milliseconds to completely come up. Change
the RS232 receiver time-out by scanning the bar code below, then scanning digits from the inside back cover of this man-
ual, then scanning Save. The range is 0 to 300 seconds. Default = 0 seconds (no time-out - always on).