Sharp R-895(AL)M Service Manual page 26

Microwave oven with grill and convection
Table of Contents

Advertisement

The I/O signal of the LSI are detailed in the following table.
Pin No.
Signal
26
P40
27
P77
28
P76
29
P75
30
P74
31
P73
32
P72
33
P71
34
P70
35
RESET
36
XCIN
37
XCOUT
38
XIN
39
XOUT
40
VSS
41
P27
42
P26
43
P25
44
P24
45
P23
DESCRIPTION OF LSI
I/O
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G7 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G6 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G5 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G4 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G3 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G2 line key on matrix is touched.
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P50-P53 terminal
while one of G1 line key on matrix is touched.
IN/OUT
Terminal not used.
IN
Connected to VC.
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "Hµ...level.
IN
Connected to VC.
OUT
Terminal not used.
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XOUT terminal.
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
OUT
Bottom heating element driving signal.
To turn on and off the relay (RY4). "L" level during grill
cooking, convection cooking or dual cooking, "H"
level otherwise. The heater relay turns on and off
within a 54 second time base in accordance with the
special program in LSI.
OUT
Convection motor driving signal.
To turn on and off shut-off relay (RY7). "L" level
during convection or dual cooking, "H" level otherwise.
(Relay RY7 does not turn on at preheating mode.)
OUT
Fan motor driving signal.
To turn on and off the fan motor relay (RY6).
"L" level during cooking, or for a while after
convection or dual cooking. "H" level otherwise.
OUT
Terminal not used.
OUT
Touch control transformer driving signal.
To turn on and off the shut off relay (RY5). If the oven has not been used for more
than 2 minutes, the relay RY5 will be turned off. The relay RY5 will be turned on
when the oven door is opened and closed.
Description
R-895M - 21
During
OFF
cooking
(Grill, Convection, Dual )
ON
H.
During
OFF
cooking
( Convection or Dual cooking )
ON
L
H.
GND
OFF
ON
L
During cooking, or for a while
after convection or dual cooking.
H.
GND
L
GND

Advertisement