The touch control section consists of the following units as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit (The Control unit consists of Power unit
and CPU unit.)
The principal functions of these units and signals commu-
nicated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit from P40, P41, P72, P73,
P74, P75, P76 and P77.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through P50 - P53
to perform the function that was requested.
Control Unit
Control unit consists of LSI, power source circuit, synchro-
nizing signal circuit, reset circuit, buzzer circuit, relay
circuit, temperature measurement circuit, indicator circuit
and back light circuit.
1) LSI
This LSI controls the temperature measurement sig-
nal, key strobe signal, relay driving signal for oven
function and indicator signal.
2) Power Source Circuit
This circuit generates voltage necessary in the control
unit.
Symbol
Voltage
VC
-5.2V
3) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It accompanies a very small error because it
works on commercial frequency.

TOUCH CONTROL PANEL ASSEMBLY

OUTLINE OF TOUCH CONTROL PANEL
Application
LSI(IC1)
R-895M - 19
4) Reset Circuit
A circuit to generate a signal which resets the LSI to the
initial state when power is supplied.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (key touch sound and completion
sound).
6) Stop Switch
A switch to "tell" the LSI if the door is open or closed.
7) Relay Circuit
To drive the magnetron, grill heating element, bottom
heating element, convection motor, fan motor, turnta-
ble motor, touch control transformer and light the oven
lamp.
8) Back Light Circuit
A circuit to drive the back light (Light emitting diodes
LD1 - LD10).
9) Indicator Circuit
This circuit consists 7-digits, 39-segments and 3-com-
mon electrodes using a Liquid Crystal Display.
10)Temperature Measurement Circuit : (OVEN THER-
MISTOR)
The temperature in the oven cavity is sensed by the
thermistor. The variation of resistance according to
sensed temperature is detected by the temperature
measurement circuit and the result applied to LSI. The
LSI uses this information to control the relay and
display units.