92,500, 92,550, 92,555, 92,558 Electronics Module
An Electronics Module error has occurred. The following troubleshooting procedure applies to
these errors.
Table 1 Applicable Fault Codes
92,500
Driver Board Serial Link Down
92,550
Safety Timer Timeout Fault
92,555
System Timer Skipped Fault
92,558
Ecm PS Link Broken
Initial Actions
•
Reboot the printer and verify the error persists.
•
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Part (Chapter 5 - Parts List)
•
Electronics Module,
PL 5.1 Item 1
Wiring and Plug/Jack References (Chapter 7 - Wiring Data)
•
Figure
1, System Block Diagram
•
Figure
2, Right Side Electronics Module P/J Locations
•
Figure
3, Left Side Electronics Module P/J Locations
•
Figure
4, Top Side Electronics Module P/J Locations
Procedure
Replace the Electronics Module
(REP
5.1).
Xerox Internal Use Only - Revised, 3rd Revision
ColorQube 8570/8870 Service Manual
92,553 Ink Loader or I/O Board Disconnected
An Ink Loader or I/O Board error has occurred. The following troubleshooting procedure
applies to this error.
92,553
Ecm Board Link Broken
Initial Actions
•
Reboot the printer and verify the error persists.
•
Verify the Ink Loader cable connection to the Ink Loader and Electronics Module.
•
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts (Chapter 5 - Parts List)
•
Ink Loader & Bezel,
PL 1.1 Item 8
•
Electronics Module,
PL 5.1 Item 1
•
Cable, Ink Loader Data,
PL 5.1 Item 11
•
Cable, I/O Board Data,
PL 5.1 Item 14
Wiring and Plug/Jack References (Chapter 7 - Wiring Data)
•
Figure
2, Right Side Electronics Module P/J Locations
•
Figure
5, I/O Board P/J Locations
•
Figure
9, I/O Board, Sensors (1 of 2)
•
Figure
9, I/O Board, Sensors (2 of 2)
•
Figure
11, Ink Loader Board P/J Locations
Procedure
Check the Ink Loader Board wiring harness connectors
nectors
P/J801
& P/J402. Are the connections secure and undamaged?
Y
N
Reseat and/or replace the wiring harness.
Replace the Electronics Module
October 2012
2-39
Table 1 Applicable Fault Code
P/J702
&
P/J401
(REP
5.1).
Fault Messages and Codes
92,500, 92,550, 92,555, 92,558 , 92,553
and I/O Board con-