11) Ice Cube Mode is not working
NO.
CHECKING FLOW
Remove Cover dispenser, then check for any
loose connection in Duct motor.
5
Unplug connector from Duct motor and check the
resistance value.
6
Check Duct Motor signal in CON 9.
NOTE: Voltage only will be appreciated during the
first second after press lever S/W after release
lever S/W voltage to close Duct Motor will be applier.
7
Refer to next diagram.
ITEM
STATUS
Pressed
Lever S/W
Released
0
1
2
12V
Duct Motor
0V
-12V
3
4
5
6
7
8
9
10
11
12
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
9.9 ~12.1 Ù
2
3
to
Other
Lever S/W
+/- 12Vdc
Pressing
Same than
Not
pressing
Pressing
voltage, but
inverted
13
- 96 -
Service Action
Go to Step 6
Service Action
Go to Step 7
Replace Duct Motor
Service Action
Go to Step 8
Other
Change PCB
Go to Step 8
Other
Change PCB