3) Abnormal Refrigerator Sensor Error (2)
NO.
CHECKING FLOW
Check for a loose connection.
1
Unplug connector in CON 7 and check between
Gray to Gray as is shown in the picture.
2
1) Remove Cover sensor.
2) Cut sensor and check resistance value.
3
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
0 Ù
Short
OFF
Open
Other
Normal
Result
0 Ù
Short
Open
OFF
- 83 -
Service Action
Go to Step 2
Service Action
Go to Step 3
Go to Step 4
Check the Temperature
and Resistance
(Temperature Chart #2)
Go to Step 6
Service Action
Replace Product
Change Sensor