4) Abnormal Defrost Sensor Error
NO.
CHECKING FLOW
Remove cover PCB, then, check for loose
connection in CON6.
1
Unplug connector and check between
Orange to Orange as is shown in the picture.
2
In Freezer compartment, unplug Defrost controller
assembly, then, check resistance value between
Orange to Orange.
Defrost Controller
Assembly connector
3
Unplug connector CON 6 from Main PCB and
check between Orange to Orange as is shown
in the picture.
4
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
0 Ù
Short
Open
OFF
Other
Normal
Result
0 Ù
Short
Open
OFF
Other
Normal
Result
0 Ù
Short
Open
OFF
Other
Normal
- 85 -
Service Action
Go to Step 2
Service Action
Go to Step 3
Check the Temperature
and Resistance
(Temperature Chart #2)
Service Action
Replace Defrost controller
assembly, then, explain to
customer.
Plug Defrost controller
assembly, then, go to
step 4.
Service Action
Replace Product
Replace Main PCB