10) Abnormal Freezer Fan Error
NO.
CHECKING FLOW
1) Reset product.
2) Remove Cover PCB.
3) Enter to TEST MODE 1 (press once TEST S/W
on Main PCB)
5
4) Check voltage in CON 6 as shown in the pictures.
Disconnect Motor connector, and check status of
plated terminals.
6
Terminals contact surface must be free of rust and
dirt. Also, the terminals must be assured with a
T.P.A., Motor wire must not have any damage.
Reset the product.
After 3 minutes execute DISPLAY CHECK MODE,
check the result.
7
RESULT & SERVICE ACTION
Result
(a) ~ (b)
Below 10V
(b) ~ (c)
0V or 5V
(a) ~ (b)
(b) ~ (c)
Result
Wire damage,rust, dirt,
TPA absences.
Normal appearance
Result
All Display
LED's are
Normal
turned ON
Freezer Fan
Error Code
Abnormal
appears
- 94 -
Service Action
Change Main PCB
Go to Step 6
Service Action
Replace Motor
Go to Step 7
Service Action
Explain to the customer
Replace Freezer
Fan Motor