2) Abnormal Refrigerator Sensor Error (1)
NO.
CHECKING FLOW
Unplug connector of Control Box.
4
Unplug connector in CON 7 and check between
White to White as is shown in the picture.
5
1) Remove the Control Box in Refrigerator sensor.
6
Check resistance value between
1
2
Resistance Values are according to Temperature
Chart table?
7
Go to Step 5.
1
4
and
.
4
3
- 82 -
RESULT & SERVICE ACTION
Result
0 Ù
Short
Replace Product
Open
OFF
Go to Step 6
Result
0 Ù
Short
Replace Control Box
Assembly or sensor
(if possible).
OFF
Open
Check the Temperature
and Resistance
Other
Normal
(Temperature Chart #2)
Go to Step 7
Result
Service Action
Normal
YES
Replace Main PCB
Sensor
NO
Abnormal
Replace Sensor
Sensor
Service Action
Service Action