Abnormal Ice Maker Unit Error - Kenmore 795.51022.001 Service Manual

Table of Contents

Advertisement

8) Abnormal Ice maker Unit Error

NO.
CHECKING FLOW
Remove Cover PCB, then check for any loose
connection in CON 8.
1
Remove Tray ice, remove screw of Ice maker unit,
quit Ice maker from holders and check for any
loose connection.
2
Check Voltage from Ice maker S/W in CON 8.
3
Check Voltage from Ice maker TEST S/W in CON 8.
Press the TEST S/W of Ice maker unit for 3 seconds,
permit finish Test Cycle before press again.
4
RESULT & SERVICE ACTION
Result
Firmly plugged
Loose
Result
Firmly plugged
Loose
Result
5V
ON
0V
Other
5V
OFF
0V
Other
Result
5V
ON
0V
Other
5V
OFF
0V
Other
- 89 -
Service Action
Go to Step 2
Service Action
Go to Step 3
Service Action
Replace Ice maker unit
Go to Step 4
Replace Main PCB
Go to Step 4
Replace Ice maker unit
Replace Main PCB
Service Action
Replace Ice maker unit
Go to Step 5
Replace Main PCB
Go to Step 5
Replace Ice maker unit
Replace Main PCB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents