Stop In Relation To The Presser Foot - Pfaff 3827-4/33 Instruction Manual

Table of Contents

Advertisement

Adjustment
12

Stop in relation to the presser foot

.05.09
12 - 12
Requirement
When adjustment foot 1 (part no. 61-111 639-20) is resting on the needle plate, stop 4
should be touching screw 2
4
2
3
6
Fig. 12 - 09
Remove presser foot.
Attach adjustment foot 1 (part no. 61-111 639-20) and lower it onto the needle plate.
Adjust screw 2 (nut 3) according to the requirement.
Remove adjustment foot 1 and replace presser foot.
4
1
5
5
1
49-028a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3827-4/34

Table of Contents