12

List of parameters

.07.03
1
101
105
106
107
110
111
112
113
116
117
199
3
301
364
382
Only appropriately trained staff may change the set values in the parameters
of user levels "B" and "C".
Audible signal of the control panel key
Speed for seam start
Speed for seam start
ON = variable (pedal-controlled) <107>)
OFF = constant (<105>)
Speed for seam start with <106> = ON
ON = limited by <105>
OFF = limited by <607>
Speed for seam end
Light barrier compensation stitches
stitches from light barrier light to seam
end
Number of stitches for light barrier
fade-out on knitted fabrics
(according to stitch size)
Start with light barrier
ON = only when light barrier is dark
OFF = also when light barrier is light
Number of soft start stitches (soft start)
Speed for soft start stitches
Speed for light barrier compensation
stitches
Switch-on voltage of the magnet for
feed reverse
ON = 24V, OFF = 32V
Meaning of feed change-over for
ON = backtack, OFF = stitch condensation
Switching threshold of the analogue
input for the thread monitor
Adjustment
A,B,C
OFF - ON
B,C
300 - 2000
B,C
OFF - ON
B,C
OFF - ON
B,C
300 - 2000
A,B,C
2 - 50
A,B,C
0 - 100
B,C
OFF - ON
A,B,C
0 - 30
B,C
30 - 640
B,C
300 - 2000
C
OFF - ON
B,C
OFF - ON
B,C
0 - 100
OFF
1200
OFF
OFF
1200
10
0
OFF
0
400
1200
OFF
ON
15
12 - 41