H(L)38DF-CLCR Corner Gas Fireplace
Heat Shields
Installing a Wall Mounted RHS102 Heat shield.
The RHS102 where the termination is closer to the fireplace than 58" horizontally.
To install the RHS102, Slide the Inner Section over the vent pipe that will connect to
the fireplace. Then fasten the vent pipe to the back of the fireplace with a minimum
of three sheet metal screws. From the outside slide the RHS102 outer section on
see Figure 19. To complete the installation fasten the Heat Shield Outer Section &
Termination frame to the structure Figure 19a.
RHS102 Heat Shield
RHS101 Heat Shield
Outer Section
Termination
Figure 19. RHS102 Installation. (Install by sliding Outer Section over vent
pipe where it passes through the combustible construction.
RHS101 Heat Shield
RHS102 Heat Shield
Outer Section
Outer Section
Termination
Figure 19a. Heat Shield. After sliding the outer section in place.
Page 14
Installation
Drywall / sheetrock
RHS102 Heat Shield Inner Section
RHS101 Heat Shield, inner Section
Vent pipe, from fireplace
Combustible
framing
Drywall / sheetrock
RHS102 Heat Shield Inner Section
RHS101 Heat Shield, inner Section
Installing a Wall Mounted RHS101 Heat shield.
The RHS101 Heat shield MUST be used where the Termination falls outside of 58"
horizontally from the fireplace. (Figure 19b and 19c) Use the RHS102 where the
termination is closer to the fireplace than 58" horizontally. To install the RHS101, Slide
the Inner Section over the vent pipe that will connect to the fireplace. Then fasten the
vent pipe to the back of the fireplace with a minimum of three sheet metal screws.
(Note: ensure you maintain the Max. 12" fireplace clearance). From the outside slide
the RHS101 outer section on see Figure 19b. To complete the installation fasten the
Heat Shield Outer Section & Termination frame to the structure Figure 19c.
RHS101 Heat Shield
Outer Section
Termination
Figure 19b. RHS101 Installation. (Install by sliding Outer Section over vent
pipe where it passes through the combustible construction.
RHS101 Heat Shield
Outer Section
Termination
Figure 19c. Heat Shield. After sliding the outer section in place.
Drywall / sheetrock
RHS101 Heat Shield, inner Section
Vent pipe, from fireplace
Combustible
framing
Drywall / sheetrock
RHS101 Heat Shield, inner Section