Section 3-3-3: Heat Shields - Montigo DelRay Square Series Installation & Maintenance Manual

Indoor direct vent gas fireplace
Table of Contents

Advertisement

Section 3-3-3: Heat Shields

Installing the included heat shield
The included Heat shield CANNOT be used WITHIN 36" horizontal or
60" vertically of the fireplace. For applications within these dimensions
the RHS10* Heat Shield MUST be used.
To install the heat sheild frame an opening in combustible construction.
Slide the Heat shield in place over the vent pipe which attaches to the
fireplace. After the fireplace and vent pipe has been installed, clearances
should match the dimensions shown.
Combustible framing
A
Figure 15.a Heat Shield Installation. (Install by sliding over vent pipe where it passes through the
combustible construction).
Wall Mounted RHS* heat shield
Vent Size
4/7 Shield
5/8 Shield
RHS100
RHS101
RHS102
RHS104
18
B
A
B
4/7
11"
1"min.
5/8
12"
1"min.
5/8
11"
3/8'' min.
5/8
11"
3/8'' min.
5/8
12"
3/8'' min.
5/10
14"
3/8'' min.
Installing a Wall Mounted Heat shield
The RHS10* Heat shield must be used if vent pipe passes through a
wall or ceiling within 6' of the unit.
To install the Heat shield, Slide the Inner Section over the vent pipe that
will connect to the fireplace. Then fasten the vent pipe to the back of
the fireplace with a minimum of three sheet metal screws. From the
outside slide the outer section on. To complete the installation fasten
the Heat Shield Outer Section & inner section to the structure.
Combustible framing
A
Figure 11. RHS10* Installation. (Install by sliding over vent pipe where it passes through the
combustible construction).
RHS10* Heat Shield Outer Section
Termination
Figure 11.b RHS10* Installation. (Install by sliding Outer Section over vent pipe where it passes
through the combustible construction.
RHS10* Heat Shield Outer Section
Termination
Figure 11.c Heat Shield. After sliding the outer section in place.
Installation
3/8'' min.
Inner
shield
Outer
shield
Drywall / sheetrock
RHS10* Heat Shield, inner Section
Vent pipe, from fireplace
Combustible framing
Drywall / sheetrock
RHS10* Heat Shield, inner Section
Vent pipe, from fireplace
XG0230 - 052020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drsq38niDrsq38ni-2Drsq38liDrsq38li-2Drsqc38niDrsqc38ni-2 ... Show all

Table of Contents