Xerox PHASER 3124 Service Manual page 111

Hide thumbs Also See for PHASER 3124:
Table of Contents

Advertisement

Rated Output Power
Items
Channel
+5V
Connector pin
CON 3
5V PIN : 11, 12
GND PIN : 8, 9
Rated output
+5V ± 5%
(4.75 ~ 5.25V)
Max. output cur-
0.8A
rent
Peak loading
1.0A
current
Ripple noise volt-
100mVp-p or less
age
Maximum output 4W
Peak output
5W
Consumption Power
No
Items
1
Stand-by
2
Printing
3
Sleep-Mode
Power cord length : 1830
Feature
Insulating resistance : 100 ohms or more (at DC 500V)
Insulating revisiting pressure : Must be no problem within 1 min. (at 1000Vac,10mA)
Leaking Current : under 3.5mA
Rising Time : within 2 Sec
Falling Time : over 20 ms
Surge : Ring Wave 6KV-500A (Normal, Common)
Environment Condition
Operating temperature range : 0 ~ 40°C
Maintaining temperature range : -20 ~ 40°C
Preserving Humidity Condition : 10% ~ 90% RH
Operating atmospheric pressure range : 1atm
EMI Requirement : CISPR ,FCC, CE, MIC,
Safety Requirement : IEC950 UL1950, CSA950, C-UL,Semko, EK, CB, CCC(CCIB), GOST,
EPA, Power Save
PHASER 3124 / PHASER 3125
Table 1: Rated Output Power
CH1
+24.0V
CON 3
24V PIN : 2, 3, 4
GND PIN : 6, 7
+24V ± 5%
(20.4 ~ 27.6V)
2.5A
2.7A
500mVp-p or less
60W
65W
CH1
1.0 A
1.0 A
0.8 A
50mm
±
General Procedures and Information
CH2
1ms
1ms
CH2
0.4 A
2.5 A
0.4 A
09/06
Remarks
Remarks
AVG : 55 Wh
AVG : 350 Wh
AVG : 10 Wh
6-17