Infrared Burner - Vulcan-Hart VBB1F Service Manual

V-series heavy duty broilers, double deck and range match models
Table of Contents

Advertisement

V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - TROUBLESHOOTING
NOTE: Grease laden air is detrimental to the life of the Infrared burner. If a technician sees a broiler with Infrared
burner mounted in a location close to a fryer or charbroiler, please recommend to the customer to move the broiler
away from the grease laden air source to prolong the life of the Infrared burner.
SYMPTOM
Flame not orange.
Burner not lighting properly or incorrect burner flame
appearance due to clogged ports.
Tiles falling out of the burner.
F45548 (0715)

INFRARED BURNER

INFRARED BURNER
1.
Orifice incorrect size or dirty.
2.
Incorrect gas pressure.
3.
Incorrect gas type.
4.
Orifice not aligned properly in venturi.
5.
Appliance not venting properly.
6.
Clogged burner ports.
7.
Burner malfunction.
1.
Broiler with Infrared burner is located too close to a
fryer or charbroiler and the grease laden air is
causing burner ports to clog. If burner ports are
found to be clogged, install a replacement burner.
See NOTE at top of page.
1.
Burner ports are clogged from the broiler operating
too close to a fryer or charbroiler that is creating
grease laden air. Clogged burner ports create poor
burner performance and cause the burner housing
to overheat and warp allowing the tiles to fall out of
burner. If tiles are missing, install a replacement
burner. See NOTE at top of page.