Table 11. Troubleshooting charts.
Device
Expansion enclosure
The SCSI expansion enclosure
used to work, but does not work
now.
Other devices
Problems such as broken cover
locks or indicator lights not
working.
Intermittent problems
A problem occurs only
occasionally and is difficult to
detect.
Keyboard, mouse, or
pointing-device
All or some keys on the
keyboard do not work.
The mouse or pointing device
does not work.
Memory
The amount of memory
displayed is less than the
amount of memory installed.
Monitor
The monitor works when you
turn on the system, but goes
blank when you start some
application programs.
80
IBM xSeries 200: User's Reference
Verify that:
1.
The cables for all external SCSI options are connected correctly.
2.
The last option in each SCSI chain, or the end of the SCSI cable, is terminated
correctly.
3.
External SCSI options are turned on. You must turn on external SCSI options
before turning on the system.
For more information, see your SCSI and expansion enclosure documentation.
Call for service.
Verify that:
1.
All cables and cords are connected securely to the rear of the system and
attached options.
2.
When the system is turned on, air is flowing from the rear of the system at the fan
grille. If there is no air flow, the fan is not working. This causes the system to
overheat and shut down.
3.
Ensure that the SCSI bus and devices are configured correctly and that the last
external device in each SCSI chain is terminated correctly.
If the items above are correct, call for service.
1.
Make sure that the keyboard cable is properly connected to the system.
2.
Make sure that the system and the monitor are turned on.
3.
Try using another keyboard.
If the items above are correct, call for service.
1.
Verify that the mouse or pointing-device cable is securely connected and the
device drivers are installed correctly.
2.
Try using another mouse or pointing device.
If the problem remains, call for service.
Verify that:
1.
The memory modules are seated properly.
2.
You have installed the correct type of memory.
3.
If you changed the memory, you must update the memory configuration with the
Configuration/Setup Utility program.
4.
All banks of memory on the DIMMs are enabled. The system might have
automatically disabled a DIMM bank if it detected a problem, or a DIMM bank
could have been manually disabled.
If the items above are correct and the screen remains blank, call for service.
Verify that:
1.
The primary monitor cable is connected to the video port.
2.
You installed the necessary device drivers for the applications.
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, refer to the information that comes with the monitor for adjusting and testing
instructions.
If you still cannot find the problem, call for service.