PCNTNW-NW-058 The adapter did not respond to the initialization command.
Explanation: The interrupt request (IRQ) setting might not be valid or the EEPROM information might
be incorrect.
Action: Make sure the IRQ settings are correct in the Configuration/Setup Utility program. See "PCI
Slot/Device Information" on page 28 for information on setting the interrupt requests. If the IRQ settings
are correct, have the system serviced.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
Explanation: The cable might be disconnected from the server Ethernet port.
Action: Verify that a cable is connected to the Ethernet port.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the device driver with a different I/O address. This
new adapter could not be found.
Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant Adapter and make sure that the
adapter is seated correctly. If the adapter is seated correctly, have the system serviced.
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The device driver tried to allocate some resources that were not available.
Action: Add or free some memory in the server. Then, restart the server.
PCNTNW-NW-073 Unable to allocate memory.
Explanation: The device driver failed to allocate the memory needed for normal operation.
Action: Add more memory, or free some memory resources in the server. Then, restart the server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt. The attempt was not
successful.
Action: Verify that the Ethernet controller is enabled. (See "PCI Slot/Device Information" on page 28.)
If the Ethernet controller is enabled, go to "Diagnostic programs" on page 110 to run the diagnostic
programs.
If you have an Ethernet adapter installed, make sure the adapter does not share an IRQ with any other
device (see "PCI Slot/Device Information" on page 28.)
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link
Support Layer (LSL).
Explanation: An error occurred while the device driver was trying to register with the LSL.
Action: Check the version of the NetWare or IntraNetWare Operating System. Make sure that this
device driver is correct for the version of NetWare or IntraNetWare that you are using. Restart the
server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, have the system serviced.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The device driver parameter block is too small.
Action: Restart the server. If the problem persists, have the system serviced.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The device driver media parameter block is too small.
Action: Restart the server. If the problem persists, have the system serviced.