1.1 Locating the Heater

The diagram below shows space and clearance re-
quirements for locating a heater within a room.
GLASS
914 mm
Figure 2. Heater Dimensions and Locations
Clearance Requirements
The top, back, and sides of the heater are defined by
stand-offs. The minimum clearance to a perpendicular
wall extending past the face of the heater is 1 in. (25
mm). The metal ends of the heater may NOT be
recessed into combustible construction.
Minimum Clearances
from the Heater to Combustible Materials
Glass Sides or Ends ..........914 ................... 36
Floor ....................................0 ......................0
Rear Flue ............................13 ................... 1/2
Metal Sides or Ends ...........13 ................... 1/2
Top ......................................64 ..................2-1/2
Ceiling* ..............................787 ...................31
* The clearance to the ceiling is measured from
the top of the unit, excluding the standoffs (see
Figures 1 and 2).
914 mm
GLASS
mm
inches
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. R • 9/15
The distance from the unit to combustible construction
is to be measured from the unit outer wrap surface to
the combustible construction, NOT from the screw
heads that secure the unit together.
Minimum Clearances
from the Flue Pipe to Combustible Materials
Vertical Sections. .............25 ................. 1
Horizontal Sections
Top .....................................76 ................. 3
Bottom ...............................25 ................. 1
Sides..................................25 ................. 1
At Wall Firestops
Top .....................................64 ..............2-1/2
Bottom ...............................13 ............... 1/2
Sides..................................25 ................. 1
For minimum clearances, see the direct flue termination
clearance diagrams on pages 6 and 7 in this manual.