Heat & Glo T-HVBI-AUB Owner's Manual page 17

Table of Contents

Advertisement

B. Installing Flue Components
After determining which direction the 45º elbow will be
used follow flueing instructions accordingly.
• This heater requires the attachment of supplied 45º
elbow to unit before connection of flue components.
• To attach the elbow flue, the elbow cover plate must
first be removed from the unit (see Figure 18).
• The elbow can be removed from the unit by aligning
the seams of the elbow to the arrows on the
surrounding heat shield (see Figure 19).
• Position the elbow in the horizontal or the vertical
position. Snap in place with the starting collar.
• Replace the elbow cover plate aligning it with the
elbow and secure in place with the 8 screws.
• Place the rope ring around the first section of pipe
and slide it up against the cover plate.
NOTE: The rope ring is needed for the heat manage-
ment and to prevent cold air infiltration.
ELBOW COVER PLATE
Figure 18
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. R • 9/15
HEAT
SHIELD
ARROWS
FRONT VIEW
Figure 19
Figure 20
WARNING
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Overlap pipe slip sections at least 1-1/2
inches (38 mm).
• Use pilot holes for screws.
• Screws must not exceed one inch
long.
• Pipe may separate if not properly
joined.
ELBOW
SEAM
ELBOW
TOP VIEW
17