NATURAL GAS - FLUEING WITH ONE 90° ELBOW
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
6' MIN. (1.83 m)
V + H = 40' MAX. (12.2 m)
PROPANE - FLUEING WITH ONE 90° ELBOW
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
6' MIN. (1.83 m)
V + H = 40' MAX. (12.2 m)
Figure 11. Flueing with One 90° Elbow
NATURAL GAS
FLUEING WITH ONE 90° ELBOW
V (FT.)
1' MIN. (305 mm)
3' MAX. (914 mm)
2' MIN. (610 mm)
6' MAX. (1.83 m)
3' MIN. (914 mm)
9' MAX. (2.7 m)
4' MIN. (1.22 m)
12' MAX. (3.6 m)
5' MIN. (1.5 m)
15' MAX. (4.5 m)
V + H = 40' MAX. (12.2 m)
Figure 12. Flueing with One 90° Elbow
H (FT.)
3' MAX. (914 mm)
6' MAX. (1.83 m)
9' MAX. (2.7 m)
12' MAX. (3.6 m)
15' MAX. (4.5 m)
18' MAX. (5.5 m)
H (FT.)
2' MAX. (610 mm)
4' MAX. (1.22 m)
6' MAX. (1.83 m)
8' MAX. (2.4 m)
10' MAX. (3.0 m)
12' MAX. (3.6 m)
FLUEING WITH ONE 90° ELBOW
H (FT.)
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
V + H = 40' MAX. (12.2 m)
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. R • 9/15
V
H
H
PROPANE
H (FT.)
2' MAX. (610 mm)
4' MAX. (1.22 m)
6' MAX. (1.83 m)
8' MAX. (2.4 m)
10' MAX. (3.0 m)
V