en | Make Connections - Power and Control
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
!
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
10.3
Ethernet Connections
Caution!
Ethernet cables must be routed through earth-grounded conduit capable of withstanding the
!
outdoor environment.
Note: Consult the National Electrical Code (NEC) for cable bundling requirements and
limitations.
Cable Type
Maximum Distance
Bandwidth
High PoE (95W required for models
with illuminators)
High PoE (60W only for models
without illuminators)
Terminal Connector
2015.12 | 3.0 | F.01U.291.520
Cat5e/Cat6e Ethernet (directly to the camera, or to a network switch
between the camera and the network)
100 m (330 ft)
10BASE-T/100BASE-TX, auto-sensing, half/full duplex
Use the 95 W midspan sold by Bosch.
Use the 60 W midspan sold by Bosch, or a midspan that is compliant to the
IEEE 802.3at, class 4 standard.
RJ45, Male