AUTODOME inteox 7000i - 2MP (in-ceiling)
10

Connection

10.1

Connecting the AUTODOME camera to the PC

Note: For simplicity, the graphic in this section is only of the camera. The graphic does not
depict a mount that you may have installed already.
1.
2.
3.
Notice!
i
The camera can also be connected directly to a PC using an Ethernet crossover cable with
RJ45 connectors (see option B below).
Notice!
i
You can also use the Bosch Video Client software application to configure the network
settings for an AUTODOME camera. Go to www.boschsecurity.com to download the
Configuration Manager software and Operating Manual.
10.2

Power Cable and Wire Distances Guides

Power
115/230 VAC
Copper Wire
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
!
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
Maximum Wire Distances from Power Supply to AUTODOME camera
24 V to AUTODOME camera
Models with IVA, Indoor
Models with IVA, Outdoor
10.3

Ethernet Connections

The camera connects to a 100 Base-TX network either directly or via a hub. Video, optional
audio input, optional audio output, and control are transmitted over a standard TCP/IP
network using the built-in Web server. In addition, power can be supplied over the Ethernet
cable using the Bosch High PoE 60W midspan (sold separately). Power can also be supplied
Bosch Security Systems
Install the camera according to the instructions in the appropriate Installation section of
this manual.
Connect an Ethernet cable from camera's RJ45 connector to a dedicated network switch
to bypass the Local Area Network (LAN).
Connect the dedicated network switch to the RJ45 connector on the PC (see option A
below).
To comply with local codes.
VA / Watts
35 / 19
60 / 55
14 AWG
16 AWG
(2.5 mm)
(1.5 mm)
99 m (325 ft)
62 m (205 ft)
58 m (190 ft)
36 m (119 ft)
Installation Manual
Connection | en
25
18 AWG
(1.0 mm)
39 m (129 ft)
23 m (75 ft)
2021-08 | 1.4 |