Setting Suction Wand Assignment/Blocking Suction Wands; Flushing And/Or Resetting Suction Wands - Viessmann VITOLIGNO 300-C Operating Instructions Manual

Pellet boiler, 18 to 48 kw
Table of Contents

Advertisement

Fuel supply
Blocking times for automatic fuel supply
3.
/
until, for the end point, "- - : - -" is displayed.
|
~
"- - : - -" appears if the start and end time are
the same.
Mo-Fr
0
2
4
6
8 10 12 14 16 18 20 22 24
- -:- - - - -:- -
?
- -:- - - - -:- -
§
Adopt with
Fig.34

Setting suction wand assignment/blocking suction wands

Note
You can set the wand assignment and blocking times
for pellet supply only for pellet supply with a vacuum
system and when using an automatic changeover unit.
Blowing pellets into the pellet store results in an
uneven height of pellets stored inside the storage area.
In order to enable the pellet store to be emptied uni-
formly, the proportion of supply volume (assignment in
%) can be adjusted individually for each suction wand.
Setting the wand assignment
Changeover unit
90 %
1
2
3
4
Select with
Fig.35
Press the following keys:
1.
for "Extended menu".
å
2.
/
for "Charging".
|
~
3.
to confirm.
d
4.
/
for "Changeover unit".
|
~
5.
to confirm.
d
The settable suction wands are shown.
6.
/
for selecting the suction wand.
Ù
Ú

Flushing and/or resetting suction wands

In the case of a shortage of pellets at one suction
wand, that wand will be blocked and a changeover to
the next suction wand occurs.
32
Std
u
Std
u
OK
(cont.)
4.
to confirm.
d
5.
until the standard display is shown (see
ä
page 13).
7.
to confirm.
d
The current fuel assignment in % (propor-
tion of supply volume) will be shown.
Changeover unit
Suction wand 2
Change with
Fig.36
8.
/
for selecting the required value of fuel
|
~
assignment.
The fuel assignment per suction wand is
adjustable from 0 to 100 %.
Choosing a setting of 0 % results in the
suction wand being blocked manually, in
other words the suction wand will not be
used.
9.
to confirm.
d
The suction wands available for selection
will be redisplayed.
10. Repeat steps 6 to 9 to select the assignment of fur-
ther suction wands.
11.
until the standard display is shown (see
ä
page 13).
Note
Check the suction wand assignment again when next
filling the pellet store and readjust the assignment if
required.
90 %

Hide quick links: