Restoring Time Phases To The Standard Settings; Setting Suction Wand Assignment/Blocking Suction Wands - Viessmann VITOLIGNO 300-C Operating Instructions Manual

Pellet boiler, 8 and 12 kw. heating system with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Blocking times for automatic fuel supply
3.
/
until, for the end point, "- - : - -" is displayed.
|
~
"- - : - -" appears if the start and end time are
the same.
Mo-Fr
0
2
4
6
8 10 12 14 16 18 20 22 24
- -:- - - - -:- -
?
u
- -:- - - - -:- -
§
u
Adopt with
Fig. 34

Restoring time phases to the standard settings

If you want to restore all time phases to their factory
settings, press the following keys:
1.
for the extended menu.
å
2.
/
for "Settings"
|
~
3.
to confirm.
d
4.
/
for "Standard setting".
|
~

Setting suction wand assignment/blocking suction wands

Note
You can set the wand assignment and blocking times
for pellet supply only for pellet supply with a vacuum
system and when using an automatic changeover unit.
Blowing pellets into the pellet storage room results in
an uneven dumping height of pellets stored inside. In
order to enable the pellet store to be emptied uni-
formly, the proportion of supply volume (assignment in
%) can be adjusted individually for each suction wand.
Setting the wand assignment
Changeover unit
90 %
1
2
3
4
Select with
Fig. 35
Press the following keys:
1.
for "Extended menu".
å
2.
/
for "Charging".
|
~
3.
to confirm.
d
(cont.)
Std
Std
OK
4.
to confirm.
d
5.
until the default display is shown (see
ä
page 14).
5.
to confirm.
d
6.
/
for "Charging".
|
~
7.
for "Yes".
|
8.
to confirm.
d
"Active" appears briefly on the display.
9.
until the default display is shown (see
ä
page 14).
4.
/
for "Changeover unit".
|
~
5.
to confirm.
d
The adjustable suction wands are shown.
6.
/
for selecting the suction wand.
Ù
Ú
7.
to confirm.
d
The current fuel assignment in % (propor-
tion of supply volume) will be shown.
Changeover unit
Suction wand 2
90 %
Change with
Fig. 36
8.
/
for selecting the required value of fuel
|
~
assignment.
The fuel assignment per suction wand is
adjustable from 0 to 100 %.
Choosing a setting of 0 % results in the
suction wand being blocked manually, in
other words the suction wand will not be
used.
Fuel supply
33