1-3-5 Installing the duplex unit (option)

<Procedure>
1. Open the left cover.
2. Remove the stop ring and the strap from the rear
side.
3. Restore the conveyor section.
4. Remove the fitting projection and pin, and then
remove the stopper from the front side.
5. Open the left cover until it is put horizontally.
6. Turn the wire guide section of the duplex unit in the
direction indicated by the arrow.
7. Insert the axis sections of the duplex unit into the U-
shape grooves of the conveyer unit.
Stop
ring
Strap
Left cover
Figure 1-3-19
Figure 1-3-20
Axis section
Duplex unit
Figure 1-3-21
2C9
Fitting projection
Stopper
Pin
Wire guide section
Axis section