Detaching And Refitting The Scanner Wires; Detaching The Scanner Wires - Kyocera KM-1620 Service Manual

Hide thumbs Also See for KM-1620:
Table of Contents

Advertisement

2C9

(2) Detaching and refitting the scanner wires

Take the following procedure when the scanner wires are broken or to be replaced.

(2-1) Detaching the scanner wires

Procedure
1. Remove the exposure lamp (see page 1-6-
17).
2. Remove the two screws holding the upper
rear cover and then the cover. Remove the
two screws holding the middle left cover and
upper left cover and then the covers.
3. Remove the screw and then the slit retainer
and slit glass. Detach the fitting portions and
then remove the front scanner cover.
4. Remove the inverter wire guide and then
detach the inverter wire from the inverter
PCB.
1-6-18
Uppeer rear cover
Middle left cover
Figure 1-6-32
Slit glass
Slit retainer
Figure 1-6-33
Inverter PCB
Figure 1-6-34
Upper left cover
Front scanner cover
Inverter wire guide
Inverter wire

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2020

Table of Contents