Detaching And Refitting The Heat Roller - Kyocera KM-1620 Service Manual

Hide thumbs Also See for KM-1620:
Table of Contents

Advertisement

2C9

(5) Detaching and refitting the heat roller

Follow the procedure below to replace the heat roller.
Procedure
1. Remove the fixing unit and separate the fixing
right unit and left unit (see page 1-6-38, 39).
2. Remove the heat roller separation claws.
(see page 1-6-41).
3. Pull out the heat roller bushing from the fixing
left unit and then remove the heat roller.
4. Replace the heat roller and refit all the
removed parts.
1-6-42
Heat roller bushing
Fixing left unit
Heat roller
Heat roller bushing
Figure 1-6-77