Furuno FCV-1900 Operator's Manual page 67

Hide thumbs Also See for FCV-1900:
Table of Contents

Advertisement

Problem
Sensitivity is low.
Extreme interference
or noise.
No depth indication.
Speed and/or water
temperature readout is
unrealistic or not
shown.
Position readout is un-
realistic or not shown.
3. MAINTENANCE & TROUBLESHOOTING
Reason, remedy
• Gain setting is too low. Raise the gain.
• Marine life is adhering to transducer face. Clean the trans-
ducer face.
• Vessel is in heavily sedimented water.
• Bottom is too soft to return an echo.
• Transducer is located too close to the engine. Relocate the
transducer.
• Ground wire has loosened or damaged. Check the wire, and
reconnect or replace it as necessary.
• Same-frequency echo sounder is operating nearby.
• Bottom is off the screen. Change the range setting.
• The sensor cable is disconnected or damaged. Check the
cable, and reconnect or replace it as necessary.
• The sensor is malfunctioning. Check the sensor.
• The cable connected to the navigation equipment is discon-
nected or damaged. Check the cable, and reconnect or re-
place it as necessary.
• The navigation equipment is malfunctioning. Check the nav-
igation equipment.
3-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-1900bFcv-1900g

Table of Contents