Symmetricom ATS-6511A User Manual page 95

Dual fiber input distribution
Table of Contents

Advertisement

Configuring a port to generate the IRIG timecode is accomplished using the irig command.
Multiple IRIG types are supported including IRIG-A, IRIG-B, and IRIG-G. The IRIG code
format is specified as a 3-digit number following the code type and is required in order to
set the output to the proper format. For instance, for IRIG-B123 the code type is B and the
code format is 123.
Configuration of a specific output can be stored on the system itself via the save command
so that replacement modules will automatically be configured with the correct output
format. However, moving the output module to a different slot causes the system to
configure the module with the default output format until reconfigured by the user.
See also: nasa36, pps, save
Syntax: irig [slot #] [port#] [Type A-H] [Code <NNN>] <epoch (AM Only)>
SLOT
PORT
CODE_FORMAT three-digit code format
EPOCH
Command Examples:
ATS-6511>irig 5 2 G 141 0
Query:
ATS-6511> settings hardware:slots:5
[tsc4387]
[ports]
[1]
[epoch_127] false
[format] B
[signal_word] 120
[type] irig
[2]
[epoch_127] false
[format] G
[signal_word] 141
[type] irig
[3]
[epoch_127] false
[format] B
[signal_word] 120
[type] irig
[4]
[epoch_127] false
[format] B
[signal_word] 120
[type] irig
slot number of the card
port number of the output
selects desired epoch ('0'-> default, '1' -> 127 epoch)