2.2.4 Firewall Settings

The system IP firewall has a default "allow all" policy. To enable the firewall, the
customer needs to create a firewall rules file on the product file system named
/mod/tsc/firewall.rules. There are example firewall rules files on the product in the
directory /usr/tsc/site/firewall. Example rules files may be copied to the correct location
and edited on the product using 'vi'. Once the rules file is setup, reboot the product.
Note that miss-configuration of the firewall can lock out network access to the product.
If that occurs, the firewall may be disabled by using a USB command port adapter, and
executing the command firewall --disable. This removes the current firewall rules and
resets it to immediately allow all traffic exposing the device.
The firewall is the standard FreeBSD IPFW.
configuration may be found here:
http://www.freebsd.org/doc/en/books/handbook/firewalls-ipfw.html

2.2.5 USB Ports

The USB ports on the rear panel allow:
Users to access the command port (ATS 94000-115200). See section 2.2.2.2. Users
can set the IP Address on the box following the instructions on section 2.2.3.B-C.
The system will automatically connect to the command port and provide the ATS-
6511> command prompt.
The ATS-6511B to communicate with a 5071A Cesium Clock (ATS 94001-5071A).
See section 2.7.
2.3

ATS-6511 Installation

The ATS-6511 is ready for installation into a standard 19" (48.3 cm) rack using either slides or
shelves and will take up 1U of rack space. The C-300-S Series rack slides from General Devices
or equivalent slides are recommended.
CAUTION: Use the screws provided with the unit to mount the rails to the side of the chassis.
If longer screws are used, you could damage the power supplies or prevent them from being
removed from the chassis.
2.4

ATS-6511 Modules

2.4.1 Power Supplies

The ATS-6511 operates with two power supplies capable of operating on different power sources.
The 4385A (AC Power Supply) and 4386A (DC Power Supply) are available. The ATS-6511 is
capable of operating on one power supply in the event the other fails or its input source fails.
Power Supply #1 is on the left and Power Supply #2 is on the right. See Appendix A for the
specifications on the Power Supplies.