Cinema Mode Set; Power Mgt Select - Mitsubishi PD-5010 Owner's Manual

Mitsubishi digital electronics plasma display owner's manual
Hide thumbs Also See for PD-5010:
Table of Contents

Advertisement

30. MENU ADJ. Gain Data
Function
The external control equipment sets the position of the OSM menu of the
plasma monitor.
Transmission Data
DFH 80H
60H
1AH 02H DATA00 DATA01 CKS
DATA00: OSM ADJ. Gain Flag
DATA01: 01H: 1
09H: 9
ACK
7FH 60H
80H
1AH 01H DATA00 CKS
DATA00: OSM ADJ. Gain Flag

31. POWER MGT Select

Function
The external control equipment switches on or off the POWER
MANAGEMENT of the plasma monitor.
Transmission Data
DFH 80H
60H
1AH 02H DATA00 DATA01 CKS
DATA00: POWER MGT Select
DATA01: 01H: ON
02H: OFF
ACK
7FH 60H
80H
1AH 02H DATA00 DATA01 CKS
DATA00: POWER MGT Select
DATA01: 01H: ON
02H: OFF
32. GRAY LEVEL Set
Function
The external control equipment sets the GRAY LEVEL of the plasma
monitor.
Transmission Data
DFH 80H
60H
C6H 01H DATA00 CKS
DATA00: GRAY LEVEL
ACK
7FH 60H
80H
C6H 01H DATA00 CKS
DATA00: GRAY LEVEL

33. CINEMA MODE Set

Function
The external control equipment switches on or off the CINEMA MODE of
the plasma monitor.
Transmission Data
02H
DATA00: CINEMA MODE Set
ACK
DATA00: CINEMA MODE Set
02H
34. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE
(inverse of image brightness) of the plasma monitor.
Transmission Data
DATA00: PLE
03H
DATA01: INVERSE
DATA02: ORBITER (PICTURE SHIFT)
03H
ACK
The plasma monitor returns the following ACK when setting the PLE,
ORBITER, and INVERSE (inverse of image brightness):
00H: 0
0FH: 15
00H: 0
0FH: 15
48
DFH 80H
60H
C1H 01H
7FH 60H
80H
C1H 01H
DFH 80H
60H
6BH 03H
3FH 60H
80H
6BH 00H
DATA00 CKS
01H: ON
02H: OFF
DATA00 CKS
01H: ON
02H: OFF
DATA00 DATA01 DATA02 CKS
01H: AUTO
02H: LOCK
01H: ON
02H: OFF
03H: WHITE
01H: ON
02H: OFF
CKS

Advertisement

Table of Contents
loading

Table of Contents