Technical Data - Hilti TE 1 Operating Instructions Manual

Hide thumbs Also See for TE 1:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15

4 Technical data

Right of technical changes reserved.
NOTE
The power tool is available in various voltage ratings. Please refer to the power tool's type identification plate for
details of its rated voltage and rated input power.
Power tool
Rated power input
Rated current input
Mains frequency
Weight in accordance with EPTA procedure 01/2003
Dimensions (L x W x H)
Hammer drilling speed
Hammering speed
Single impact energy in accordance with EPTA proced-
ure 05/2009
Other information about the power tool
Drilling performance in medium-hard concrete
Protection class as per EN
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise and vibration information (measured in accordance with EN 60745):
Typical A-weighted sound power level
Typical A-weighted emission sound pressure level
Uncertainty for the given sound level as per EN 60745
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Hammer drilling in concrete, a
Uncertainty (K)
h, HD
TE 1
650 W
Rated voltage 110 V: 6.5 A
Rated voltage 120 V: 6.5 A
Rated voltage 127 V: 6.5 A
Rated voltage 220 V: 3.1 A
Rated voltage 230 V: 3.0 A
Rated voltage 240 V: 2.9 A
50...60 Hz
2.4 kg
330 mm x 79 mm x 203 mm
0...930/min
0...4,500/min
1.5 J
∅ 8 mm: 25 cm³/min
∅ 10 mm: 33 cm³/min
∅ 12 mm: 35 cm³/min
Protection class II (double insulated) as perEN 60745‑1
100 dB (A)
89 dB (A)
3 dB (A)
Measured in accordance with EN 60745‑2‑6
15 m/s²
1.5 m/s²
en
15

Advertisement

Table of Contents
loading

Table of Contents