10

SERVICE PROCEDURES

Note: Prior to carrying out any service procedures, ensure that the machine has been
isolated from the power supply.
10.1

Accessing Components in Console Area

(a) Remove the lid.
(b) Remove the two screws at the rear of the console securing the console to the top deck.
(c) Tilt the console forward.
10.2

Removal of Display Module

(a) Follow
procedures
components in console area (refer to
Section 10.1).
(b) Disconnect the wiring harness from the
motor control module.
(c) Remove the 4 screws securing the display
module to the console
(d) Remove the display module from the
housing by pivoting the display away from
the console.
Reassembly:
Refit in the reverse manner.

10.3 Removal of motor Control Module

(a) Follow procedures for removal of Display
Module. (Refer to Section 10.2).
(b) Disconnect all wiring harnesses to the
Motor Control Module.
(c) Remove the pressure tube by squeezing on
the legs of the spring clip. Pull gently on
the tube to slide it off the spigot. Note: If
too much force is used on removal or
reinsertion, damage to the pressure
transducer may occur.
(d) Pull the tab on the top deck harness clamp
towards the front to release the Motor
Control Module.
(e) Lift the Motor Control Module upwards at
the front and out.
Reassembly:
Refit in reverse manner. Important: When refitting pressure tube to pressure transducer ensure
that the pressure tube is clear of any water droplets before operating the machine on a fill cycle. If
the basket is full of water, drain the water then blow down the tube before reconnecting.