478182
24.
(00011000) Dispensing Type Not Set
The Motor Control Module has found that the dispensing type needs to be set.
Reselect the dispensing type for the machine by using the DISPENSING TYPE SETTING.
Action, LED Machines: To set the dispensing type, turn the power on at the power point
Action, LCD Machines: To set the dispensing type, turn the power on at the power point
26.
(00011010) Detergent Valve Fault.
The Motor Controller module has detected that the detergent valve (purple clip) is faulty. It
determines this by measuring voltages from the valve diagnostic circuit. The most likely
cause is that the valve harness has not been connected correctly or the valve is open
circuit.
Primary Source:
Action:
Secondary Source: Detergent Valve.
Action:
Tertiary Source:
Action:
27.
(00011011) Fabric Softener Valve Fault.
The Motor Controller module has detected that the fabric softner valve (yellow clip) is faulty.
It determines this by measuring voltages from the valve diagnostic circuit. The most likely
cause is that the valve harnesses has not been connected correctly or the valve is open
circuit.
Primary Source:
Action:
Secondary Source: Fabric Softener Valve.
Action:
Tertiary Source:
Action:
and off at the console. Ensure no LED's are lit before proceeding to
the next step, if so press the power button to turn them off.
Press and hold Wash Temperature button then press Power.
Press the Temperature button to scroll through the dispensing type
options, stopping at the desired dispensing type setting.
Cold LED = No dispensing
Warm LED = Double dispensing
Hot LED
= Triple dispensing
Press Power button to confirm the setting and to exit this mode.
and off at the console. Ensure no LCD is not lit before proceeding to
the next step, if so press the power button to turn it off.
Press the Start/Pause and Left Scroll (left arrow) buttons at the same
time
Use the Left and Right Scroll (arrow) buttons to select the appropriate
dispensing type
Press Power button to confirm the setting and to exit this mode.
Wiring.
Check the valve harness is correctly fastened to the valve or the pins
are not bent backwards.
Check the valve coil is not faulty (i.e. not open circuit – See 1.8).
Motor Controller module.
Replace the Motor Controller module.
Wiring.
Check the valve harness is correctly fastened to the valve or the pins
are not bent backwards.
Check the valve coil is not faulty (i.e. not open circuit – See 1.8).
Motor Controller module.
Replace the Motor Controller module.