Cleaning And Maintenance; Basic Information; Cleaning The Fire Trough; Cleaning The Flame Temperature Sensor - RIKA INDUO Operating Manual

Table of Contents

Advertisement

Display
DISCHARGE MOTOR
JAMMED
INSERTION MOTOR
JAMMED

13. CLEANING AND MAINTENANCE

Basic Information

Note
Your stove must be switched off and cooled before any maintenance work is
performed. Only work on the unit when the mains plug has been disconnected.
Note
SERVICE appears in the display after consumption of 700 kg pellets. Cleaning
and maintenance is to be performed. Then this message can be acknowledged
by pressing ENTER and operation can be continued. The number of SERVICE
messages is stored in the background.
The frequency with which the stove requires cleaning and the maintenance
intervals depend on the fuel you use. High moisture content, ash, dust and chips
may more than double the maintenance required. We would like to again point
out that only tested and recommended pellets or logs may be used as fuel.
Tip
wood as fertiliser - The mineral content of the wood remains in the combustion
chamber as ash as a residue of the combustion. This is an excellent fertiliser
for all plants in the garden; it is a completely natural product. The ash should
be stored first and slaked with water.
Note
Ash may contain embers – only place ash in sheet steel containers.
Cleaning the f ire trough
Despite the automatic ash dumping prior to and during heating operation, care
should be taken that the air intake openings are not blocked with ash or clinker.
Remove the clinker using the brush supplied and vacuum out the fire trough.
Do not damage the ignition when cleaning with the brush.
The discharge motor for pellet conveying out of
ERROR
the container is blocked and can no longer be
controlled correctly.
The insertion motor for conveying pellets to the fire
ERROR
trough is blocked and can no longer be controlled
correctly.
Meaning
Note
Clean the fire trough regularly. Only clean when cold, when embers are
extinguished!
Note
To prevent "clinker formation" it is advisable to operate the stove sometimes
on higher power level, or according to its combination function the operation
with logs.
Cleaning the flame temperature sensor
Remove the dust deposits from the sensor at regular intervals. Use a clean
cleaning cloth or newspaper.

Empty the ash drawer

Empty the ash drawer regularly. The ash drawer is simply pulled forward with
the combustion chamber door open
Action to be taken
Operation can not be continued, please call
customer service immediately.
Operation can not be continued, please call
customer service immediately.