TABLE OF CONTENT 1. PREFACE Explanations to symbols ...................................3 Spare part overview exploded diagram ..............................4 Spare part overview article numbers .................................6 Dimensions ......................................7 Amount of fuel ......................................7 Technical data ......................................7 Packaging .........................................7 Electrical connection ....................................7 2. IMPORTANT INFORMATION General warning and safety information ..............................8 First heating......................................8 Safety distances ......................................8 Prior to set up ......................................9...
Dimensions Technical data Description Measure Data RO-T3 Heating capacity range [kW] 3 - 10 RO-T2 RO-S Room heating capacity depending on house [m³] 70 - 260 coating Fuel consumption [kg/h] bis 2,4 Pellet container lid capacity [l/kg] -/~34 Electric supply 230V/50Hz ~20cm Average electrical input...
This can sometimes lead to slight bending or cracking noises. This is normal and rules applicable locally. and is no reason for a complaint. RIKA stoves should only be installed in rooms with normal humidity (dry areas according to VDE 0100 Part 200). The furnaces are not splash water First heating protected and may not be installed in wet areas.
Prior to set up Stoves type 1 (BA 1): These may only be operated with the combustion chamber door closed. Floor bearing capacity Ensure that the substructure is capable of bearing the weight of the stove prior Suitable for multiple occupancy. (note the different country regulations) to set-up.
3. BRIEF INFORMATION ON FUEL PELLETS Your pellet stove is only approved for the burning of pellets of tested quality. What are pellets? Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufacturers. Wood pellets are a standardised fuel. Every manufacturer must adhere to certain conditions in order to enable flawless, energy-efficient heating.
4. BRIEF INFORMATION ON COMBUSTIBLE LOGS Suitable fuels and fuel amounts Output controlling Your stove is generally suitable for burning dry firewood. You can also burn The output of your stove is regulated manually or via the Rikatronic-control. combustibles such as wood briquettes. Please observe that the output of your stove also depends on the chimney draught and the amount of fuel added.
Note is performed. The stove stops, the automatic cleaning tilts the grid and then The innovative technology of our combination stove INDUO offers you a re-ignites the stove. The status indicator CLEANING appears on the display maximum of heating comfort, depending on the availability of the fuel the continuously.
The stove can also be pushed on this cardboard or carpet. Feeding in external combustion air We recommend original flue pipes from RIKA for proper connection. only for devices which are able to run in room-air independent operation. Connection to the chimney Combustion air must be fed to the stove from outside via a sealed pipe for operation independent of the room air.
7. ASSEMBLY/DISMANTLING STONE AND OPTIONS Open the two hex head bolts using a suitable socket spanner and remove the stone holder. Note Only work on the unit when the mains plug has been disconnected and the stove has cooled completely. Note During assembly / dismantling do not allow objects (screws etc.) to fall into the pellet container –...
Conversion to flue pipe connection rear Cut the perforated opening in the left rear wall with a hacksaw and deburr the edges with a round file. Remove the left rear wall by opening the 3 top hex head bolts. The rear wall is mounted at the floor, it is removed by pressing it back slightly and lifting.
8. INTERNAL CONTROLS TOUCH DISPLAY The stove has a modern programmable microprocessor control. The individual NAVIGATION-Button stove functions can be set by the user via the touch display. Pressing the NAVIGATION button takes the user to the corresponding main menu. Note Manipulation of hardware components may only be performed by trained specialist dealers and service.
Putting into Operation First Steps Once the stove has been reconnected to the mains, the display changes to the Note date and time setting by pressing the screen. The unit may only be put into operation when assembled completely! The input specified here only has to be made on first use; however it may be changed at any time in the main menu SETUP settings.
Activating the Burnback and Flue Gas Flap HOME - Main Menu The burnback flap must be pulled out using the handle supplied (1) until it The HOME main menu is the starting point of the stove control system and is remains open.
MODE - Mode Selection Any deviation between the current displayed and actual room temperature can be compensated for. The various heating modes are selected in this display. Mode Select 15:55 Su 15.03.2015 If a modem is connected, the stove GSM function can be activated and the PinCode required entered numerically.
INFO - Main Menu INFO – Outputs The most important current parameters can be viewed in INFO – main menu. Output Su 15.03.2015 15:55 Info Su 15.03.2015 15:55 Discharge Motor [‰] Input Discharge Current Output Dischargem. Error Parameters Discharge Motor [‰] SUBMENU ITEMS Current output of screw motor conveying pellets out of the container Inputs...
INFO – Parameters Screen Saver Depending on the interval set without touching the display, the lighting is dimmed and power-saving mode is activated, a freeze image appears. Parameters Su 15.03.2015 15:55 Renewed touching of the display activates the lighting and switches to the HOME main menu Operat.
This requires a 2-pole cable of 0.5 – 0.75 mm² cross-section that you have to connect instead of the cable bridge fitted for The RIKA firenet module connects your stove to the Internet. You can operate delivery the stove with any Internet-enabled device (tablet, PC, Smartphone ...).
Correct heating up counteracts above all excessive smoke during heating up. Amount filled for heating up ~ 2kg Amount added up to 1.3 - 2.6kg You can order the RIKA firelighter with the number E15718 at your RIKA dealer.
Automatic operation Manual Regulation Once the combustion chamber door has been closed, the operating status log (CURRENTLESS OPERATION) check is issued on the touch display. Note Manual Mode Manual Mode Su 15.03.2015 15:55 The combi stove must be disconnected from the mains for manual operation. Heating Power Split Logs Check Note...
Combined Operation Automatic fuel detection makes changing between pellet and log operation possible. 2 possibilities of combined operation are stated as examples: Automatic ignition of logs Place 2 logs in the combustion chamber before you start pellet operation. Ensure that one of the two logs lies above the fire trough to facilitate burning and shorten the ignition time.
12. WARNING AND ERROR MESSAGES During operation, unforeseen circumstances or intervention by the user may lead to malfunctions or interruptions of the control process. There is a differentiation between warnings and error messages. Warnings are interruptions caused by the user; they can be eliminated by correct actions. Error messages are malfunctions of components or discharges during operation.
Errors Display Meaning Action to be taken There are no longer sufficient pellets in the Acknowledge error message and refill pellets. ERROR container. PELLETS Ignition cannot be concluded due to lack of ignition Acknowledge error message and check pellet ERROR detection.
Display Meaning Action to be taken The discharge motor for pellet conveying out of Operation can not be continued, please call ERROR the container is blocked and can no longer be customer service immediately. DISCHARGE MOTOR controlled correctly. JAMMED The insertion motor for conveying pellets to the fire Operation can not be continued, please call ERROR trough is blocked and can no longer be controlled...
Cleaning flue pipes Dismantle the two cleaning covers behind the ash drawer by loosening the 4 milled nuts. The flue pipes should be cleaned at least 2 x a year or after approx. 700 kg pellets. The flues are behind the combustion chamber. Remove the hexagonal screws of both covers at the rear side.
Cleaning flue gas deflector section Lift the cover of the stove by carefully pressing upwards and place it on a soft, clean base. Re-assembly the parts removed in reverse order. Cleaning the pellet container Open the fixing bolts of the top cover plate and place it on a soft, clean base. Do not refill the completely empty container immediately;...
14. PROBLEMS POSSIBLE SOLUTIONS Problem 1 Problem 2 Fire burns with weak, orange flame. Pellets heap up in fire trough, window Stove smells strongly and / or fumes are emitted sooted up. Cause(s) pellet / log operation Cause(s) pellet operation Burning-in phase (taking into service) Insufficient combustion air Stove has accumulated dust and/or dirt...
Note points, is a document. Please return 1 completed protocol for putting into service to RIKA Innovative Ofentechnik GmbH, Müllerviertel 20, 4563 Micheldorf, Austria. Warranty terms Difference between warranty (statutory) and guarantee (voluntary), terms of guarantee, determination of wearing parts, reference to pellet quality to be Electrical periphery used and the consequences of poor quality.
Page 34
Please contact your warranty partner for any warranty questions or claims. This is your dealer or installation company. No warranty claims can be accepted without proper putting into operation, proper operation according to the operating instructions and the supplements in this information sheet. Protocol for putting into operation for RIKA pellet and combi stoves Date:____________________...
In case of doubt as well as missing or incorrect translations, the German version is the only valid one. For the purpose of timely damage limitation, the warranty claim on the part of the claimant is to be enforced at the RIKA dealer in writing using the invoice and stating the purchase date, model name, serial number and reason for complaint.