Table of Contents

Advertisement

Quick Links

INDUO
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for RIKA INDUO

  • Page 1 INDUO Operating Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENT 1. PREFACE Explanations to symbols ...................................3 Spare part overview exploded diagram ..............................4 Spare part overview article numbers .................................6 Dimensions ......................................7 Amount of fuel ......................................7 Technical data ......................................7 Packaging .........................................7 Electrical connection ....................................7 2. IMPORTANT INFORMATION General warning and safety information ..............................8 First heating......................................8 Safety distances ......................................8 Prior to set up ......................................9...
  • Page 3: Preface

    INFO – Outputs ....................................20 INFO – Parameters ....................................21 Screen Saver ......................................21 Additional Information ..................................21 9. COMFORT OPTIONS RIKA room sensor/RIKA radio room sensor ............................22 RIKA GSM Control ....................................22 RIKA interface for various options .................................22 External room thermostat ..................................22 External connection cable bridge ................................22 Option RIKA firenet ....................................22...
  • Page 4: Spare Part Overview Exploded Diagram

    Spare part overview exploded diagram Kit Fluegas ap...
  • Page 5 10 6 11 0 10 9 10 5 10 2 10 0 10 4 10 3 10 2 10 1 10 8 10 7...
  • Page 6: Spare Part Overview Article Numbers

    Cover cpl., black L02044 Holder dump grate B16963 Right side panel black E15143 Cover AH metallic B16680 Cleaning cover Flame temperatur probe B16676 Induo E15356 Cover AH black Milled nut (cleaning N111883 cover) B16574 Touch-Display N110461 Double ball catch Flue pipe attachments...
  • Page 7: Dimensions

    Dimensions Technical data Description Measure Data RO-T3 Heating capacity range [kW] 3 - 10 RO-T2 RO-S Room heating capacity depending on house [m³] 70 - 260 coating Fuel consumption [kg/h] bis 2,4 Pellet container lid capacity [l/kg] -/~34 Electric supply 230V/50Hz ~20cm Average electrical input...
  • Page 8: Important Information

    This can sometimes lead to slight bending or cracking noises. This is normal and rules applicable locally. and is no reason for a complaint. RIKA stoves should only be installed in rooms with normal humidity (dry areas according to VDE 0100 Part 200). The furnaces are not splash water First heating protected and may not be installed in wet areas.
  • Page 9: Prior To Set Up

    Prior to set up Stoves type 1 (BA 1): These may only be operated with the combustion chamber door closed. Floor bearing capacity Ensure that the substructure is capable of bearing the weight of the stove prior Suitable for multiple occupancy. (note the different country regulations) to set-up.
  • Page 10: Brief Information On Fuel Pellets

    3. BRIEF INFORMATION ON FUEL PELLETS Your pellet stove is only approved for the burning of pellets of tested quality. What are pellets? Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufacturers. Wood pellets are a standardised fuel. Every manufacturer must adhere to certain conditions in order to enable flawless, energy-efficient heating.
  • Page 11: Brief Information On Combustible Logs

    4. BRIEF INFORMATION ON COMBUSTIBLE LOGS Suitable fuels and fuel amounts Output controlling Your stove is generally suitable for burning dry firewood. You can also burn The output of your stove is regulated manually or via the Rikatronic-control. combustibles such as wood briquettes. Please observe that the output of your stove also depends on the chimney draught and the amount of fuel added.
  • Page 12: Technology And Safet Y Functions

    Note is performed. The stove stops, the automatic cleaning tilts the grid and then The innovative technology of our combination stove INDUO offers you a re-ignites the stove. The status indicator CLEANING appears on the display maximum of heating comfort, depending on the availability of the fuel the continuously.
  • Page 13: Installing The Stove

    The stove can also be pushed on this cardboard or carpet. Feeding in external combustion air We recommend original flue pipes from RIKA for proper connection. only for devices which are able to run in room-air independent operation. Connection to the chimney Combustion air must be fed to the stove from outside via a sealed pipe for operation independent of the room air.
  • Page 14: Assembly/Dismantling Stone And Options

    7. ASSEMBLY/DISMANTLING STONE AND OPTIONS Open the two hex head bolts using a suitable socket spanner and remove the stone holder. Note Only work on the unit when the mains plug has been disconnected and the stove has cooled completely. Note During assembly / dismantling do not allow objects (screws etc.) to fall into the pellet container –...
  • Page 15: Conversion To Flue Pipe Connection Rear

    Conversion to flue pipe connection rear Cut the perforated opening in the left rear wall with a hacksaw and deburr the edges with a round file. Remove the left rear wall by opening the 3 top hex head bolts. The rear wall is mounted at the floor, it is removed by pressing it back slightly and lifting.
  • Page 16: Internal Controls Touch Display

    8. INTERNAL CONTROLS TOUCH DISPLAY The stove has a modern programmable microprocessor control. The individual NAVIGATION-Button stove functions can be set by the user via the touch display. Pressing the NAVIGATION button takes the user to the corresponding main menu. Note Manipulation of hardware components may only be performed by trained specialist dealers and service.
  • Page 17: Putting Into Operation

    Putting into Operation First Steps Once the stove has been reconnected to the mains, the display changes to the Note date and time setting by pressing the screen. The unit may only be put into operation when assembled completely! The input specified here only has to be made on first use; however it may be changed at any time in the main menu SETUP settings.
  • Page 18: Activating The Burnback And Flue Gas Flap

    Activating the Burnback and Flue Gas Flap HOME - Main Menu The burnback flap must be pulled out using the handle supplied (1) until it The HOME main menu is the starting point of the stove control system and is remains open.
  • Page 19: Mode - Mode Selection

    MODE - Mode Selection Any deviation between the current displayed and actual room temperature can be compensated for. The various heating modes are selected in this display. Mode Select 15:55 Su 15.03.2015 If a modem is connected, the stove GSM function can be activated and the PinCode required entered numerically.
  • Page 20: Info - Main Menu

    INFO - Main Menu INFO – Outputs The most important current parameters can be viewed in INFO – main menu. Output Su 15.03.2015 15:55 Info Su 15.03.2015 15:55 Discharge Motor [‰] Input Discharge Current Output Dischargem. Error Parameters Discharge Motor [‰] SUBMENU ITEMS Current output of screw motor conveying pellets out of the container Inputs...
  • Page 21: Info - Parameters

    INFO – Parameters Screen Saver Depending on the interval set without touching the display, the lighting is dimmed and power-saving mode is activated, a freeze image appears. Parameters Su 15.03.2015 15:55 Renewed touching of the display activates the lighting and switches to the HOME main menu Operat.
  • Page 22: Comfort Options

    This requires a 2-pole cable of 0.5 – 0.75 mm² cross-section that you have to connect instead of the cable bridge fitted for The RIKA firenet module connects your stove to the Internet. You can operate delivery the stove with any Internet-enabled device (tablet, PC, Smartphone ...).
  • Page 23: Modes

    Correct heating up counteracts above all excessive smoke during heating up. Amount filled for heating up ~ 2kg Amount added up to 1.3 - 2.6kg You can order the RIKA firelighter with the number E15718 at your RIKA dealer.
  • Page 24: Automatic Operation

    Automatic operation Manual Regulation Once the combustion chamber door has been closed, the operating status log (CURRENTLESS OPERATION) check is issued on the touch display. Note Manual Mode Manual Mode Su 15.03.2015 15:55 The combi stove must be disconnected from the mains for manual operation. Heating Power Split Logs Check Note...
  • Page 25: Combined Operation

    Combined Operation Automatic fuel detection makes changing between pellet and log operation possible. 2 possibilities of combined operation are stated as examples: Automatic ignition of logs Place 2 logs in the combustion chamber before you start pellet operation. Ensure that one of the two logs lies above the fire trough to facilitate burning and shorten the ignition time.
  • Page 26: Flow Diagram Pellet Log Operation

    11. FLOW DIAGRAM PELLET LOG OPERATION...
  • Page 27: Warning And Error Messages

    12. WARNING AND ERROR MESSAGES During operation, unforeseen circumstances or intervention by the user may lead to malfunctions or interruptions of the control process. There is a differentiation between warnings and error messages. Warnings are interruptions caused by the user; they can be eliminated by correct actions. Error messages are malfunctions of components or discharges during operation.
  • Page 28: Errors

    Errors Display Meaning Action to be taken There are no longer sufficient pellets in the Acknowledge error message and refill pellets. ERROR container. PELLETS Ignition cannot be concluded due to lack of ignition Acknowledge error message and check pellet ERROR detection.
  • Page 29: Cleaning And Maintenance

    Display Meaning Action to be taken The discharge motor for pellet conveying out of Operation can not be continued, please call ERROR the container is blocked and can no longer be customer service immediately. DISCHARGE MOTOR controlled correctly. JAMMED The insertion motor for conveying pellets to the fire Operation can not be continued, please call ERROR trough is blocked and can no longer be controlled...
  • Page 30: Cleaning Flue Pipes

    Cleaning flue pipes Dismantle the two cleaning covers behind the ash drawer by loosening the 4 milled nuts. The flue pipes should be cleaned at least 2 x a year or after approx. 700 kg pellets. The flues are behind the combustion chamber. Remove the hexagonal screws of both covers at the rear side.
  • Page 31: Cleaning Flue Gas Deflector Section

    Cleaning flue gas deflector section Lift the cover of the stove by carefully pressing upwards and place it on a soft, clean base. Re-assembly the parts removed in reverse order. Cleaning the pellet container Open the fixing bolts of the top cover plate and place it on a soft, clean base. Do not refill the completely empty container immediately;...
  • Page 32: Problems Possible Solutions

    14. PROBLEMS POSSIBLE SOLUTIONS Problem 1 Problem 2 Fire burns with weak, orange flame. Pellets heap up in fire trough, window Stove smells strongly and / or fumes are emitted sooted up. Cause(s) pellet / log operation Cause(s) pellet operation Burning-in phase (taking into service) Insufficient combustion air Stove has accumulated dust and/or dirt...
  • Page 33: Instructions For Commissioning Protocol

    Note points, is a document. Please return 1 completed protocol for putting into service to RIKA Innovative Ofentechnik GmbH, Müllerviertel 20, 4563 Micheldorf, Austria. Warranty terms Difference between warranty (statutory) and guarantee (voluntary), terms of guarantee, determination of wearing parts, reference to pellet quality to be Electrical periphery used and the consequences of poor quality.
  • Page 34 Please contact your warranty partner for any warranty questions or claims. This is your dealer or installation company. No warranty claims can be accepted without proper putting into operation, proper operation according to the operating instructions and the supplements in this information sheet. Protocol for putting into operation for RIKA pellet and combi stoves Date:____________________...
  • Page 35: Guarantee

    In case of doubt as well as missing or incorrect translations, the German version is the only valid one. For the purpose of timely damage limitation, the warranty claim on the part of the claimant is to be enforced at the RIKA dealer in writing using the invoice and stating the purchase date, model name, serial number and reason for complaint.
  • Page 36 Technical and design changes, as well as typesetting and printing errors reserved © 2015 | RIKA Innovative Ofentechnik GmbH RIKA Innovative Ofentechnik GmbH 4563 Micheldorf / Austria, Müllerviertel 20 Telefon: +43 7582 686 - 41, Fax-DW: 43 E-Mail: verkauf@rika.at RIKA.AT...

Table of Contents