12. WARNING AND ERROR MESSAGES

During operation, unforeseen circumstances or intervention by the user may lead to malfunctions or interruptions of the control process. There is a differentiation
between warnings and error messages. Warnings are interruptions caused by the user; they can be eliminated by correct actions. Error messages are malfunctions
of components or discharges during operation. These must be acknowledged by the user so that operation can continue.
Note
If error messages recur several times, customer service is to be notified immediately. In the case of error messages that pose a safety risk, burnback and flue
gas flap is activated and the stove is automatically switched off.

Warnings

Display
DOOR
OPEN
Please Close Door
PELLET HOPPER
LID OPEN
Please Close Door
PELLET HOPPER
LID AND
DOOR OPEN
Please Close Doors
AIR FLAPS
ON CALIBRATION
Please Wait
BURNBACK AND
FLUE GAS FLAP
Pull Down Lever
ROOMSENSOR
SIGNAL LOST
Manual Mode
PLEASE PERFORM
SERVICE
Display for open combustion chamber door.
WARNING
Display for open pellet container lid.
WARNING
Display for open combustion chamber door and
WARNING
pellet container lid.
The air flaps are re-calibrated on every new start of
WARNING
the stove control system.
The two safety devices burnback flap and flue gas
WARNING
flap are not in heating position. Only currentless log
operation is possible as long as these devices are
not in position. This warning is shown after various
error messages and after power cuts.
There is no valid signal between the stove control
WARNING
system and the room sensor.
Perform service (maintenance)
NOTE
Meaning
Action to be taken
Close the combustion chamber door
Close the pellet container lid.
Close the combustion chamber door and the pellet
container lid.
This process takes up to 4 minutes and cannot be
interrupted.
The burnback flap (1) must be pulled out using the
handle supplied until it remains open. The flue gas
flap lever must then be pressed down (2) until it
engages.
Check if the sensor is plugged in correctly
Perform service (see CLEANING AND MAINTE-
NANCE), after finishing the service press the button
„Feed Rate Service" at "Resets" at the setup menu.
|27