Combined Operation

Automatic fuel detection makes changing between pellet and log operation
possible.
2 possibilities of combined operation are stated as examples:
Automatic ignition of logs
Place 2 logs in the combustion chamber before you start pellet operation.
Ensure that one of the two logs lies above the fire trough to facilitate burning
and shorten the ignition time.
Start pellet operation by pressing the ON button. The combi stove starts in
ignition status, changes to log check after successful ignition and to log
operation status once logs have been detected.
Note
If no more logs are reloading the pellet operation starts automatically again
because the unit is still turned on.
Automatic log detection during pellet operation
Open the combustion chamber door during pellet control operation and place
on the first load 2 logs á ~ 0,7kg in the chamber. Ensure that the two logs lie
above the fire trough to facilitate burning and shorten the ignition time.
Once you have closed the combustion chamber door. Status changes from
control operation to log check and after log detection to log operation.
Once the log has burned down, pellet operation starts automatically since the
combi stove is still switched on.
Note
If no more logs are reloading the pellet operation starts automatically again
because the unit is still turned on.
Note
The stove may change to standby operation in AUTOMATIC or COMFORT
mode since there is no demand on the control system (outside the heating
times and actual room temperature above the set room temperature).
If you switch the combi stove off during log operation by pressing the OFF
button, the status changes to neutral after burn-down of the log
|25