Table of Contents

Advertisement

Errors

Display
NO
PELLETS
NOT
IGNITED
AIR FLAPS
DEFECT
GRID
DEFECT
DISCHARGE MOTOR
DEFECT
INSERTION MOTOR
DEFECT
STOVE
OVERHEATED
FLAME SENSOR
DEFECT
FAN
DEFECT
There are no longer sufficient pellets in the
ERROR
container.
Ignition cannot be concluded due to lack of ignition
ERROR
detection.
The air flaps required for automatic air regulation
ERROR
cannot move to their position correctly.
The dump grate cannot complete the dump process
ERROR
provided for.
The discharge motor for pellet conveying out of the
ERROR
container can no longer be actuated.
The insertion motor for pellet conveying into the
ERROR
burnpot can no longer be actuated.
The STL (safety temperature limiter) has activated.
ERROR
The stove overheated and switched off automati-
cally due to a safety risk.
The flame temperature sensor in the combustion
ERROR
chamber does not give a realistic temperature to
the stove control system.
The flue gas blower specified speed was not
ERROR
reached.
Meaning
Action to be taken
Acknowledge error message and refill pellets.
Acknowledge error message and check pellet
supply container. Open combustion chamber door
and clean fire trough if necessary. Stove can then
be restarted.
Acknowledge error message and again wait for air
flap calibration.
Acknowledge error message and check for any
blockage of the dump grate at the fire trough.
Acknowledge error message and restart stove.
Acknowledge error message and restart stove.
Manually deblock STL at stove rear wall (press)
acknowledge error message and restart stove
Acknowledge error message and restart stove.
Acknowledge error message and restart stove.